Blog

Blog

HALYARD Sequential Sterilization Wrap

HALYARD Sequential Sterilization Wrap

Posted by Pankaj Dhiman on Feb 5th 2024

HALYARD Sequential Sterilization Wrap: Benefits, Features, Application and Top 5 Products


In the fast-paced world of healthcare, where infection control is paramount, sterile instruments are the cornerstone of safe and successful procedures. But how do you ensure those instruments remain sterile from the moment they're sterilized to the point of use? Enter the HALYARD Sequential Sterilization Wrap*, a trusted name in sterile processing departments worldwide.


This blog delves into the features, benefits, and applications of the HALYARD* Sequential Sterilization Wrap, exploring why it's the go-to choice for countless healthcare professionals across the US.


Unveiling the Key Features:


  • Strength and Durability: Made from low-linting SMS fabric, the HALYARD* wrap boasts KC600, the highest strength level in the Kimguard® line. This translates to resistance against tears, flames, abrasion, and lint, ensuring the integrity of your sterile packs throughout handling and storage.
  • Enhanced Microbial Barrier: Powered by POWERGUARD technology*, the wrap offers superior protection against bacteria, viruses, and fungi. This added layer of defense minimizes the risk of contamination, safeguarding both patients and healthcare workers.

  • Sterilization Compatibility: Whether you use pre-vacuum steam or ethylene oxide (EO) sterilization, the HALYARD* wrap facilitates optimal sterilant penetration. This ensures all instruments within the pack are effectively sterilized, meeting the highest standards of sterility assurance.

  • Package Integrity: The wrap is designed to maintain package integrity (MPI), complying with stringent FDA requirements. This means the wrap won't tear or leak during handling, transportation, or storage, guaranteeing the sterility of your instruments until the point of use.

  • Clear Instructions: Each wrap features clear and concise instructions for use, adhering to FDA guidelines. This ensures proper handling and minimizes the risk of user error, promoting consistent sterility practices.

  • Safety First: The HALYARD* wrap carries a Class 1 flammability rating, signifying its low flame spread and smoke generation. This prioritizes safety in the sterile processing department, minimizing fire hazards.

  • Made in the USA: For added peace of mind, the HALYARD* wrap is proudly manufactured in the United States, ensuring quality and adherence to strict domestic regulations.

Top 5Be Halyard Sterilization Wrap


1. Halyard H200 Quick Check Sterilization Wrap

O&M Halyard Inc 34185 - McKesson Medical-Surgical

  • HALYARD* Sterilization Wraps are intended to be used to enclose another medical device that is to be sterilized by a health care provider using: Pre-vacuum steam at 270°F/132°C for 4 minutes, 100% ethylene oxide (EO) with a concentration of 725-735 mg/L at 131°F/55°C and 40%-80% relative humidity for 60 minutes, Lumen, Non Lumen and Flexible Cycles in the STERIS V-PRO® 1, STERIS V-PRO® 1 Plus and STERIS V-PRO® maX Low Temperature Sterilization Systems, Gravity steam at 250°F/121°C for 30 minutes (25 minute dry time for Models 100, 200 and 300 and 30 minute dry time for Models 400, 500 and 600), and Advanced Sterilization Products STERRAD® Sterilization Systems: STERRAD® 50, 100S and 200, STERRAD® NX [Standard Cycle, Advanced Cycle], STERRAD® 100NX [Standard Cycle, Flex Cycle, EXPRESS Cycle, DUO Cycle)
  • Comes with white and blue colors that are bonded together - inspect trays easier and faster than ever
  • H200 grade is for linen towels, packs and gowns, light basin sets and single instruments - for 3 to 6 lbs tray weight
  • Made from recyclable number 5 polypropylene fabric
  • Superior microbial barrier protection with patented Powerguard technology
  • Do not use wrap in dry heat or radiation sterilization methods

2. Halyard H200 Sequential Sterilization Wrap


Halyard H200 Sequential Sterilization Wrap


The Halyard H200 Sequential Sterilization Wrap is a great way to keep your medical instruments and equipment sterile. This wrap is available in a variety of sizes to fit your needs.


3. Halyard H300 Quick Check Sterilization Wrap


Halyard H300 Quick Check Sterilization Wrap


  • HALYARD* Sterilization Wraps are intended to be used to enclose another medical device that is to be sterilized by a health care provider using: Pre-vacuum steam at 270°F/132°C for 4 minutes, 100% ethylene oxide (EO) with a concentration of 725-735 mg/L at 131°F/55°C and 40%-80% relative humidity for 60 minutes, Lumen, Non Lumen and Flexible Cycles in the STERIS V-PRO® 1, STERIS V-PRO® 1 Plus and STERIS V-PRO® maX Low Temperature Sterilization Systems, Gravity steam at 250°F/121°C for 30 minutes (25 minute dry time for Models 100, 200 and 300 and 30 minute dry time for Models 400, 500 and 600), and Advanced Sterilization Products STERRAD® Sterilization Systems: STERRAD® 50, 100S and 200, STERRAD® NX [Standard Cycle, Advanced Cycle], STERRAD® 100NX [Standard Cycle, Flex Cycle, EXPRESS Cycle, DUO Cycle)
  • Superior microbial barrier protection with patented Powerguard technology

  • Do not use wrap in dry heat or radiation sterilization methods
  • H400 grade is for most basin sets, instrument sets, procedure trays, large linen packs and drills - for 9 to 13 lbs tray weight

4. Halyard H500 Quick Check Sterilization Wrap


  • HALYARD* Sterilization Wraps are intended to be used to enclose another medical device that is to be sterilized by a health care provider using: Pre-vacuum steam at 270°F/132°C for 4 minutes, 100% ethylene oxide (EO) with a concentration of 725-735 mg/L at 131°F/55°C and 40%-80% relative humidity for 60 minutes, Lumen, Non Lumen and Flexible Cycles in the STERIS V-PRO® 1, STERIS V-PRO® 1 Plus and STERIS V-PRO® maX Low Temperature Sterilization Systems, Gravity steam at 250°F/121°C for 30 minutes (25 minute dry time for Models 100, 200 and 300 and 30 minute dry time for Models 400, 500 and 600), and Advanced Sterilization Products STERRAD® Sterilization Systems: STERRAD® 50, 100S and 200, STERRAD® NX [Standard Cycle, Advanced Cycle], STERRAD® 100NX [Standard Cycle, Flex Cycle, EXPRESS Cycle, DUO Cycle)

  • Comes with white and blue colors that are bonded together - inspect trays easier and faster than ever
  • Made from recyclable number 5 polypropylene fabric

  • H500 grade is for heavy instrument sets, retractors and applications where frequent handling occurs - for 13 to 17 lbs tray weight
  • Superior microbial barrier protection with patented Powerguard technology

  • Do not use wrap in dry heat or radiation sterilization methods

Halyard H500 Quick Check Sterilization Wrap


5. Halyard H500 Sequential Sterilization Wrap


The Halyard H500 Sequential Sterilization Wrap is a heavy-duty wrap that is available in several sizes. This wrap is designed to be used with a sequential sterilization system and is made from a durable material that is easy to clean.


Halyard H500 Sequential Sterilization Wrap


Benefits that Matter:


By choosing the HALYARD* Sequential Sterilization Wrap, you're not just getting a product; you're investing in a multitude of benefits:


  • Enhanced Patient Safety:  Reduced risk of infections translates to improved patient outcomes and reduced healthcare costs associated with complications.
  • Staff Protection: The wrap's barrier properties safeguard healthcare workers from exposure to harmful pathogens, promoting a safer work environment.
  • Efficiency and Cost-Effectiveness: Durable and reliable, the wrap minimizes the risk of damaged packs and instruament reprocessing, leading to cost savings and improved efficiency.
  • Compliance with Regulations: The wrap's adherence to FDA and other regulatory guidelines ensures peace of mind and avoids potential compliance issues.
  • Confidence and Trust: Backed by a trusted brand with a long-standing reputation for quality and innovation, the HALYARD* wrap instills confidence in sterile processing professionals.


Applications Across the Healthcare Spectrum:


The HALYARD* Sequential Sterilization Wrap finds its application in various healthcare settings, including:

  • Hospitals: Sterilizing surgical instruments, procedure trays, and basin sets.
  • Dental clinics: Sterilizing dental instruments and equipment.
  • Ambulatory surgery centers: Ensuring sterility of instruments used in outpatient procedures.
  • Veterinary clinics: Maintaining sterility of surgical instruments for animal care.
  • Research laboratories: Sterilizing equipment and materials used in research activities.


Choosing the Right Wrap for Your Needs:


The HALYARD* Sequential Sterilization Wrap comes in various sizes and configurations to cater to diverse needs. It's crucial to choose the right size and type of wrap based on the instruments or supplies you're sterilizing. Consider factors like:


  • Size of instruments/supplies: Choose a wrap large enough to comfortably accommodate the items without overcrowding.
  • Sterilization method: Ensure the wrap is compatible with your chosen sterilization method (steam or EO).
  • Frequency of use: Opt for more durable wraps if you'll be using them frequently.
  • Budget: Consider the cost-effectiveness of different options while prioritizing quality and safety.

Conclusion:

The HALYARD* Sequential Sterilization Wrap is more than just a packaging solution; it's a cornerstone of infection prevention and control practices. By offering superior strength, enhanced microbial barrier, and compliance with regulations, it empowers healthcare professionals to deliver safe and effective care to their patients. So, if you're looking for a reliable and trustworthy wrap to safeguard your sterile instruments, look no further than the HALYARD* Sequential Sterilization Wrap.