Icu Medical Jelco Iv Catheters (V1001_405411)
Icu Medical Jelco Iv Catheters (V1001_405411)
ICU Medical Jelco IV Catheters
The leading standard peripheral I.V. catheter. The FEP polymer construction and "J"-point needle design allow clinicians to easily feel the vein entry. Clinician rely on these catheters for their ease of use starting arterial lines and gaining I.V. access. The thin wall catheter design provides higher flow rates than standard wall catheters, often allowing for use in a smaller gauge device.
For enhanced securement, try the winged catheter. The flexible wings follow the contours of any site allowing a more secure attachment on even the most active patients.
The ICU Medical Jelco IV Catheters are a trusted choice among healthcare professionals in the United States, known for their reliability and superior performance in intravenous therapy. Designed with precision, these IV catheters offer optimal patient comfort and safety during vascular access procedures. Whether used in emergency situations or routine medical care, Jelco IV Catheters ensure smooth insertion and minimize the risk of complications.
Crafted with a sharp, double-beveled needle, these catheters allow for easy and accurate venipuncture. The catheters are made from high-quality, biocompatible materials that reduce the chances of irritation or allergic reactions, making them suitable for patients with sensitive skin. Available in various sizes, ICU Medical Jelco IV Catheters cater to different patient needs, ensuring flexibility and adaptability in medical settings.
These catheters also feature a flashback chamber that provides immediate visual confirmation of vein entry, enhancing the success rate of first-time insertions. With an innovative design that promotes ease of use, Jelco IV Catheters are a reliable solution for healthcare providers aiming to deliver safe and effective intravenous therapy.
ICU Medical Jelco IV Catheters Features:
- Sharp, Double-Beveled Needle: Ensures smooth and precise venipuncture, reducing patient discomfort.
- Biocompatible Material: Made from high-quality materials that minimize irritation and allergic reactions.
- Flashback Chamber: Provides immediate visual confirmation of vein entry for increased insertion accuracy.
- Various Sizes Available: Offers flexibility to meet diverse patient needs, from pediatric to adult care.
- Color-Coded Hubs: Facilitates quick identification of catheter size, ensuring efficiency in emergency situations.
- Secure Fit: Designed to stay in place, reducing the risk of accidental dislodgment.
ICU Medical Jelco IV Catheters Specification:
- Needle Type: Sharp, double-beveled
- Material: Biocompatible, latex-free
- Flashback Chamber: Yes
- Hub Type: Color-coded, Luer lock
- Sterility: Sterile, single-use
- Packaging: Individually wrapped for safety
- Usage: IV therapy, emergency care, routine venipuncture
How to Use ICU Medical Jelco IV Catheters:
-
Preparation:
- Gather all necessary supplies, including the Jelco IV Catheter, gloves, antiseptic swabs, and a tourniquet.
- Wash your hands thoroughly and wear gloves to maintain a sterile environment.
-
Patient Preparation:
- Explain the procedure to the patient to ensure their comfort and cooperation.
- Apply a tourniquet above the insertion site to engorge the vein.
-
Insertion:
- Clean the insertion site with an antiseptic swab and allow it to dry.
- Hold the catheter at a 15-30 degree angle and insert it into the vein using a smooth, controlled motion.
- Once blood is seen in the flashback chamber, advance the catheter into the vein while withdrawing the needle.
-
Secure the Catheter:
- Release the tourniquet and secure the catheter hub with adhesive tape or a sterile dressing.
- Attach the IV line to the catheter’s Luer lock hub.
-
Monitoring:
- Regularly check the insertion site for signs of infection or dislodgment.
- Replace the catheter as recommended by clinical guidelines or if complications arise.
Storage and Handling:
- Store in a cool, dry place away from direct sunlight.
- Ensure the packaging is intact before use to maintain sterility.
Warnings:
- Single-use only. Do not reuse.
- Dispose of used catheters in accordance with local medical waste disposal regulations.
Shipping
bttn offers a variety of shipping options to best fit your orders. All orders over $199 include free shipping. For those under $199, a $10 fee will be added, while those under $99 will have a $20 fee added for shipping. Products weighing over 100lbs will be marked in our system as “freight collect” and someone from our team will reach out to you directly to confirm shipping costs. For more information on our shipping policy, please refer to our shipping policy page.
Return Policy
Cancellation Policy
Most of our products ship out within 24-48 business hours, depending on availability. If you wish to cancel your order, you must request a cancellation the same day your order is placed. Please contact support@bttnusa.com with your order number to request a cancellation. After your cancellation has been confirmed, you will be issued a refund to your original form of payment. If your order is shipped before cancellation is confirmed, you will not be able to cancel your order.
Damaged or Defective Products
Please inspect your order upon receipt and contact bttn immediately if your product is damaged, defective, or incorrect. If your product is damaged, you need to contact support@bttnusa.com within 72 hours of receiving your order. Please include your order number, a description of the issue, and a photo. If damage is reported after 72 hours, your product will no longer be eligible for return. Additionally, if a photo is not included in your correspondence, we will be unable to verify eligibility for a prepaid return label.
Return Policy
bttn will only accept returns up to 14 business days after your delivery date. Your product must be returned in the same packaging, condition and quantity it was delivered.
If your product is eligible for return contact support@bttnusa.com In the email, place the order number in the subject line, include a brief description of the reason for returning, and attach any applicable pictures.
bttn will not accept returns for the following products:
- Any item which has been used after opening, stickered, marked, defaced, or is without all original packaging, labeling, package inserts, or operating manuals
- Products that are regulated and/or require a medical license to purchase
- Products that are refrigerated
- Products labeled ‘hazardous’
- Products labeled ‘sterile’ or ‘sterilized’
- Products used to analyze human body tissue
- Products containing hazardous chemicals
- Products that are non-stock (product status is 14-21 Days) or have been drop-shipped (product status is 7-14 Days) directly from the manufacturer non-stocked
- All brands of COVID tests
- All discontinued products
- All narcotics and other controlled substances
- All syringes
- All short-dated (e.g. less than 90-day shelf life), outdated, or seasonal products
- N95 Masks - N95 masks are designed to fit securely on the face and may cause discomfort, bruising and or broken skin on the bridge of the nose. bttn will not accept returns on
- N95/KN95 masks due to the way the may fit or feel while wearing them
Upon receiving your return request, our supply team will determine if your product qualifies for a return based on the above guidelines. Customers are responsible for the shipping costs associated with returning the product, unless the product arrived damaged (please review damage products policy above) or you received the wrong product.
If your order qualifies for a return label (products that are damaged or defective within policy terms), our supply team will issue you a return label through email. You will have 14 business days to drop off your product at the designated courier location.
The product will be inspected for quality assurance upon delivery and a refund will be issued to the original form of payment. Once the refund has been issued it can take up to 7-10 business days to reflect on your original form of payment.
Any requests to return products after 14 days from receipt will be denied.